Gate Operator Event (transaction) Reports
The tracker interface board sends the following gate operator data to the DKS access control system.
This data is stored in a separate file in the access system and can be viewed by clicking the GATE
button on the transaction report screen in the DoorKing Remote Account Manager for Windows
software. Each event is date and time stamped.
Event (transaction) Description
Gate Operate 100 Times Transaction sent each time gate operator goes through 100 operations. If 10 of
these transactions show on report, the operator has cycled 1000 (10 x 100) times.
Gate Forced An attempt was made to force open the gate.
Gate Hit Obstruction The Type A (inherent) entrapment prevention device was activated.
Gate Power On Power applied to the operator control board.
Gate Key 1 On 5 Minutes Input is activated continuously (shorted) for at least 5-minutes.
Gate Key 2 On 5 Minutes Input is activated continuously (shorted) for at least 5-minutes.
Gate Reverse On 5 Minutes Reverse input is activated continuously (shorted) for at least 5-minutes.
Gate 5/14 On 5 Minutes Partial open input is activated continuously (shorted) for at least 5-minutes.
Gate Input On 5 Minutes Rels Shorted input has been cleared.
Gate Stop On 5 Minutes Stop (3-button) input is activated continuously (shorted) for at least 5-minutes.
Gate Reverse Loop On 5
Minutes
Detector plugged into control board reverse port activated at least 5-minutes.
Gate Exit Loop On 5 Minutes Detector plugged into control board open port activated at least 5-minutes.
1601 Up On 5 Minutes Up input to 1601/1602 operator activated continuously for at least 5-minutes.
1601 Down On 5 Minutes Down input to 1601/1602 operator activated continuously for at least 5-minutes.
1601 Up Loop On 5 Minutes Detector plugged into control board up port activated at least 5-minutes.
1601 Up Loop Down 5 Minutes Detector plugged into control board down port activated at least 5-minutes.
1601 Power On Power applied to the operator control board.
1601 Input On 5 Minutes Rels Shorted input has been cleared.
Pedestrian Gate Stuck Open Alarm relay activated on 2351 board.
Pedestrian Gate Closed Alarm reset activated on 2351 board.
1601 Hit Obstruction The Type A (inherent) entrapment prevention device was activated.
Gate Open On 5 Minutes Open (3-button) input is activated continuously (shorted) for at least 5-minutes.
Gate Close On 5 Minutes Close (3-button) input is activated continuously (shorted) for at least 5-minutes.
Gate 1 Power Off Power applied to the operator control board has been lost.
1601 Power Off Power applied to the operator control board has been lost.
Open Beam On 5 Minutes Input is activated continuously (shorted) for at least 5-minutes.
Close Beam On 5 Minutes Input is activated continuously (shorted) for at least 5-minutes.
Open Edge Activated Reverse edge has been activated.
Close Edge Activated Reverse edge has been activated.
Gate Shut Down Slide gate hard shutdown, entrapment alarm activated.
Reset Pushed Slide gate reset button activated.
Alarm On Swing gate hard shutdown, entrapment alarm activated.
Reset Pushed Swing gate reset button activated.
Beam On 5 Minutes Swing gate beam input is activated continuously (shorted) for at least 5-minutes.