Page 1

1601/1602 barrier gate operator - installation guide

Page 2

1601-065-M-05-07installation guide 11    s#OMMONs2ELAYs2ADIO0OWER/PTIONAL5P)NPUTS$OWN)NPUTS2EVERSE)NPUTS2ADIO)NPUTSDOWN

Page 3 - 4 installation guide

1601-065-M-05-0712 installation guideelectrical installation/primary-secondary control wiring9ELLOW0RIMARY3ECONDARY"ROWN/RANGE'RAY1234567891

Page 4

1601-065-M-05-07installation guide 13electrical installation/pams wiringDKSDKS1234567891011121314SW112123456783WING'ATE/PERATOR#ONTROLLER&quo

Page 5 - 6 installation guide

1601-065-M-05-0714 installation guideelectrical installation/gate tracker wiring1234567891011121314SW1 SW212345678123456783- DATA OUT2- DATA IN1- COMM

Page 6 - '2/5.$,%6%

1601-065-M-05-07installation guide 15Loop detector wiring shown is for DoorKing model 9405 and 9406 plug-In loop detectors only.electrical installati

Page 7 - 8 installation guide

1601-065-M-05-0716 installation guideelectrical installation/entry lane application$OWN,OOP123456789101112131412345678123456783- DATA OUT2- DATA IN1-

Page 8

1601-065-M-05-07installation guide 17electrical installation/exit lane application SW-1, switch 4 must be ON.$OWN,OOP%XIT,OOP1234567891011121314123

Page 9 - 10 installation guide

1601-065-M-05-0718 installation guideSW-1, switch 4 must be ON.electrical installation/ticket spitter application4ICKET%JECT,OOP$OWN,OOP12345678910

Page 10 - 2ADIO0OWER

1601-065-M-05-07installation guide 19Spacing of the loops is critical when using this configuration. Be sure that the loops are spaced as shown in t

Page 11 - 3ECONDARY

1601-065-M-05-0720 installation guideelectrical installation/timer down application1234567891011121314SW2783- DATA OUT2- DATA IN1- COMMONTB 2TB 1DOWNP

Page 12 - #BSSJFS"SN0QFSBUPS

barrier gate operator installation guide for use with models 1601-080/0811602-080/081 with circuit board 1601-010 rev. V or higher supplemental manual

Page 13 - 4O4RACKER"OARD

1601-065-M-05-07installation guide 21arm installation/hubUsing the supplied hardware install and secure the arm hub as shown.(2) Hex Bolt(1) Mounting

Page 14 - $OWN,OOP

1601-065-M-05-0722 installation guidearm installation/aluminum-plastic-wood/././&&/&&/././&&/&&/././&&/&&a

Page 15 - 16 installation guide

1601-065-M-05-07installation guide 23arm installation/wishbone/././&&/&&/././&&/&&Install the inside/outside counterw

Page 16 - SW-1, switch 4 must be ON

1601-065-M-05-0724 installation guidesettings/control boardSettings and adjustments should be made after installation and wiring to the operator(s) is

Page 17 - SW-1, switch 4 must be ON

1601-065-M-05-07installation guide 25settings/magnetic limit1234567891011121314SW1 SW21234567812345678ONPOWEROFFAUTODOWNUP12345678ONOFFSW167891011121

Page 18

1601-065-M-05-0726 installation guidesettings/direction check1234567891011121314SW1 SW21234567812345678ONPOWEROFFAUTODOWNUP&,)0-!'.%43SW1 SW

Page 19 - 20 installation guide

1601-065-M-05-07installation guide 27The ERD (electronic reversing device) in the operator is not intended to replace external reversing devices such

Page 20

1601-065-M-05-0728 installation guidesettings/switch descriptions & functionsSwitch Function Setting Description1Down Active when arm is full up D

Page 21 - 22 installation guide

1601-065-M-05-07installation guide 29accessory installation/reversing edge.06/5*/($)"//&-3&7&34*/(&%(&1234567891011121314T

Page 22

1601-065-M-05-0730 installation guideaccessory installation/fan kit3&"37*&8An optional fan kit is recommended in hot humid climates to p

Page 23 - 24 installation guide

1601-065-M-05-074 installation guidegeneral information/safety informationSPEEDLIMIT53PEED"UMP3PEED"UMP1610 Speed BumpsSpeed Limit SignOpe

Page 24 - 3,)$%!$*534

1601-065-M-05-07installation guide 31accessory installation/heater kitTo avoid the gearbox oil from freezing an optional heater kit is recommended in

Page 25 - &,)0-!'.%43

1601-065-M-05-0732 installation guidetechnical information/wiring diagram1PTJUJPO4XJUDI1PXFS.PUPS#MBDL8IJUF$JSDVJU#PBSE7"$1PXFS

Page 26

1601-065-M-05-07installation guide 33technical information/wiring diagram-convenience open1PTJUJPO4XJUDI1PXFS"$.PUPS#MBDL8IJUF$JSDVJU#

Page 27 - SW2 (bottom switch)

1601-065-M-05-0734 installation guideComponent Maintenance Description 3 6 12Arm Check for alignment, tightness and wear. Belt Check for alignme

Page 28 - .06/5*/($)"//&

1601-065-M-05-07installation guide 35technical information/troubleshootingCondition Possible SolutionOperator will not run – power LED on control boa

Page 29 - 3&"37*&8

1601-065-M-05-0736 installation guidetechnical information/accessoriesThe following accessories are available for 1601 operators.Loop Detector/plug di

Page 30

DKS DoorKing, IncDesigned by DKS, DoorKing in California1601-065-M-05-07

Page 31 - 32 installation guide

1601-065-M-05-07installation guide 5general information/glossaryRESIDENTIAL VEHICULAR OPERATOR-CLASS - A vehicular operator (or system) intended for

Page 32

1601-065-M-05-076 installation guidegeneral information/specificationsoperator The 1601 operator has been designed for high usage single lane (14 feet

Page 33 - 34 installation guide

1601-065-M-05-07installation guide 7hMIN'2/5.$,%6%,operator installation/surface operatorConcrete must be even and leveled, avoiding any oper

Page 34 - • Keying Devices

1601-065-M-05-078 installation guideThe operator’s access door must face the opposite side of traffic.operator installation/surface operatorPlace the

Page 35 - 36 installation guide

1601-065-M-05-07installation guide 91. 115 VAC NEUTRAL 2. 115 VAC POWER 3. 115 VAC MOTOR POWER4. 115 VAC MOTOR POWER 5. 24 VAC RADIO RECEIV

Page 36

1601-065-M-05-0710 installation guide",!#+#!07)2%.547()4%'.$",!#+6!#",!#+6!#6!#()'(6/,4!&ap